This page is also available in French. Switch to French

This page is also available in Spanish. Switch to Spanish

OCPP 1.6 and 2.0.1, supported in detail

Connect Business works with OCPP 1.6 and 2.0.1 chargers from any manufacturer. Every charger has its own authentication key, talks to the platform over a secure WebSocket channel, and can be managed remotely.

Illustrative interface. Sample data.

Any manufacturer

  • Any OCPP charger

    Connect Business works with OCPP 1.6 and 2.0.1 chargers from any manufacturer.

    Supported chargers
  • Not on OCPP?

    For chargers that do not use OCPP, Kinethra can add the manufacturer's own protocol on its side. Talk to us.

  • Compatibility testing

    Kinethra offers compatibility testing for chargers.

Well-known chargers that work with Connect Business

  • ABB
  • ABL
  • ADS Tec
  • Alpitronic
  • Amina
  • Autel
  • Besen
  • Circontrol
  • DEFA
  • Delta Electronics
  • Easee
  • Elinta Charge
  • Elli
  • EVBox
  • EVEUS
  • Garo
  • go-e
  • Grasen
Supported chargers

A secure channel for every charger

Three chargers of three makers (a DC fast charger, a charger on a post and a slimmer one on a post), each on its own locked data line marked with its OCPP version, 1.6, 2.0.1 and 1.6; the three lines run side by side, never merging, each to its own server cabinet of the platform. The card reads OCPP 1.6 and 2.0.1, chargers of any manufacturer; secured: WSS, a key per charger.
0212Available12 1.62.0.11.6 OCPP1.62.0.1Chargers of any manufacturerSecuredWSS · A key per charger
  • Unique authentication key

    Every charger has its own OCPP authentication key.

  • Secure WebSocket (WSS)

    Chargers talk to the platform over a secure WebSocket channel.

  • Setup details in Connect Business

    Each charger's OCPP setup details are shown in Connect Business.

Remote commands

  • Sessions

    Start and stop charging remotely.

  • Availability and reset

    Change availability, reset a charger, or disconnect it.

  • Firmware

    Run firmware updates.

  • Configuration

    Read and change a charger's configuration.

  • Local authorization list

    Keeps chargers working on a weak network.

  • Data Transfer

    Send vendor-specific commands.

What you see for each charger

An underground garage: a pedestal charger charges a car, an RFID card at its screen; its dashed data link to the platform climbs the concrete wall and runs away in stretches that pale, with gaps that grow, until it ends. The card reads: charging, authorized from the local list, weak network.
P2 P2 48 ACharging ChargerChargingAuthorized from the local listWeak network
  • OCPP tab

    The authentication key, BootNotification and supported OCPP profiles.

  • Charger card

    Serial number (the OCPP identity), last heartbeat and commissioning date.

  • Connectors

    Each connector's type, for example Type 1 or NACS, with its status, power, voltage and current.

    Operations
  • On a weak network

    A local authorization list keeps the charger working on a weak network.

Connector statuses as OCPP defines them

  • Available
  • Preparing
  • Charging
  • SuspendedEV
  • SuspendedEVSE
  • Finishing
  • Reserved
  • Unavailable
  • Faulted

Plug & Charge, V2G and grid signals

  • Plug & Charge (ISO 15118)

    Kinethra supports Plug & Charge (ISO 15118) with compatible chargers and vehicles.

  • Bidirectional charging

    Kinethra supports bidirectional charging, V2G and V2H, with compatible chargers and vehicles.

  • Smart charging on grid signals

    Kinethra supports smart charging based on grid signals.

    Connect Utility
  • OCPP 2.1

    OCPP 2.1 support is in development.

Check your charger

Tell us the manufacturer, model, OCPP version and firmware, and request compatibility testing.

Request compatibility testing
A test bench in a lab: a wall charger on a test board over the bench charges into a portable load tester on it, an opened shipping carton stands on the shelf under it, a laptop shows a log, and the charger’s dashed data line runs along the wall toward the platform. The card reads compatibility testing: OCPP 1.6 supported, OCPP 2.0.1 supported, without OCPP the maker’s protocol.
48 ACharging Compatibility testingOnlineOCPP 1.6SupportedOCPP 2.0.1SupportedWithout OCPPMaker’s protocol

Questions about OCPP

Which OCPP versions are supported?

OCPP 1.6 and OCPP 2.0.1. OCPP 2.1 support is in development.

Does it work with my charger brand?

Connect Business works with OCPP 1.6 and 2.0.1 chargers from any manufacturer. For chargers without OCPP, Kinethra can add the manufacturer's own protocol on its side.

Does Kinethra support Plug & Charge?

Yes. Kinethra supports Plug & Charge (ISO 15118) with compatible chargers and vehicles.

Does Kinethra support V2G and V2H?

Yes. Kinethra supports bidirectional charging, V2G and V2H, with compatible chargers and vehicles.

Can I send vendor-specific commands?

Yes, through OCPP Data Transfer.

How does a charger authenticate?

Every charger has its own unique OCPP authentication key and talks to the platform over a secure WebSocket channel (WSS).

What happens on a weak network?

A local authorization list keeps chargers working on a weak network.

Where do I find a charger's OCPP setup details?

Connect Business shows each charger's OCPP setup details.

Book a demo

What happens next

  1. Tell us about your network.
  2. Meet a Kinethra specialist.
  3. Get your chargers live on Kinethra.
  • 40,000+ chargers onlineOn the Kinethra platform.
  • OCPP 1.6 and 2.0.1Kinethra works with OCPP chargers from any manufacturer.
  • No commission on charging revenueKinethra takes none.
  1. 01Contact
  2. 02Business
  3. 03Request

Step 1 of 3

We use your details to answer your request. See our Privacy Policy for details.