Share one circuit between many chargers
EV charger load management without a separate meter: load balancing lets several chargers share one circuit's limited capacity without exceeding it. The split is recalculated continuously as vehicles start and stop charging.
- P1-14CA*LKR*E00114*120 A
- P1-15CA*LKR*E00115*120 A
- P1-16CA*LKR*E00116*120 A
- P1-17CA*LKR*E00117*120 A
What it does
Two algorithms
Proportional
Used when no charger has priority. Current is split equally between active sessions, and freed capacity is shared again.
Prioritized
Used when you set a priority charger. It is served first, and the remainder is shared between the others.
You choose the priority
The administrator chooses the priority charger. Only one charger in a group can have priority.
Unused capacity is shared
If the priority charger does not need its full share, the unused capacity goes to the other chargers.
How to set it up
Open the location
Load-balancing groups are set up for chargers within one location.
Create a group
Create a load-balancing group for chargers that share one circuit's capacity.
Set phases and current
Choose single-phase or three-phase, and enter the maximum group current.
Choose a priority charger, or none
With no priority charger the group uses the proportional algorithm; with one, it uses the prioritized algorithm.
Limit single chargers if needed
Give any charger its own current limit.
Questions about load management
How does the prioritized algorithm decide?
The administrator chooses one priority charger per group. It is served first, and the remaining current is shared between the other chargers. Capacity it does not need goes to the others.
What happens when a car stops charging?
The split is recalculated continuously as vehicles start and stop charging. With the proportional algorithm, the freed capacity is shared between the sessions that are still active.
What if a charger loses its link to the platform?
It depends on the algorithm. By default, the charger keeps its last current limit.
Do I need a meter?
No. Load balancing needs no separate meter.
How many chargers can share a group?
There is no fixed maximum number of chargers in a group.
Can I set the limit per phase?
Yes. Set the group limit in amps, per phase if needed.
Can charging follow grid signals?
Yes. Kinethra supports smart charging based on grid signals.
Book a demo
- Tell us about your network.
- Meet a Kinethra specialist.
- Get your chargers live on Kinethra.
- 40,000+ chargers onlineOn the Kinethra platform.
- OCPP 1.6 and 2.0.1Kinethra works with OCPP chargers from any manufacturer.
- No commission on charging revenueKinethra takes none.
We use your details to answer your request. See our Privacy Policy for details.