This page is also available in French. Switch to French

This page is also available in Spanish. Switch to Spanish

Charger offline: heartbeat gaps and what to do

The charging management system has not heard from the charger. Any message counts: the system "SHOULD assume availability of a Charge Point whenever a PDU has been received" (OCPP 1.6, §4.6).

What it means

Offline is not an OCPP error code.

It is what the management system concludes when no message arrives for longer than expected.

A charger stuck in Pending or Rejected registration can also look offline (OCPP 1.6, §4.2).

Likely causes

Anything that stops messages reaching the system: the charger has no power, or its internet link (Wi-Fi, Ethernet or cellular) is down.

On a connection secured with TLS, the charger ends the connection when the management system's certificate is not valid, and it reports an InvalidCentralSystemCertificate security event. A charger without the correct date and time cannot validate that certificate (Improved security for OCPP 1.6-J, §2.1, §2.4).

First three checks

  • 1.

    Did any message arrive recently? Then the charger is online and only skipping heartbeats.

  • 2.

    Are site neighbours offline too? Then check the site network or power.

  • 3.

    When it comes back, read its BootNotification status and the StatusNotifications it sends. It reports any status that changed while it was offline, and may report errors that happened then (OCPP 1.6, §4.2, §4.9).

What to do

  • Safe remote action

    TriggerMessage confirms two-way communication and changes nothing (OCPP 1.6, §5.17). Reset is a last resort: it ends the session (OCPP 1.6, §5.14).

  • Dispatch when

    It stays offline after the site network and power are confirmed working, or the antenna or modem is visibly damaged.

  • Do not

    Do not reset first.

What to tell the customer

"Your charger is offline.

Depending on its settings it may still charge, but we can't see or control it until it is back online."

A detection rule to start from

HeartbeatInterval is the time without any OCPP exchange after which the charger should send a heartbeat (OCPP 1.6, §9.1.10).

When no OCPP message arrives for longer than HeartbeatInterval plus a margin you choose: if one charger at the site is silent, treat it as single-unit network trouble; if all are, check the site network or power. With OCPP-J, heartbeats are not mandatory (OCPP 1.6, §4.6), so first confirm that the charger sends them.

What industry data shows

Researchers tested all 655 CCS fast-charging ports at open public stations in the nine counties of the San Francisco Bay Area.

23.5% did not work, and network failures were one of the causes, alongside screens, payment, charge initiation and broken connectors (Rempel et al., Human Factors, 2023).

A 2024 NREL report cites 2023 network-monitoring data from one US charging network: station connectivity accounted for 55% of the causes of no-charge events (NREL, August 2024).

The two figures measure different things. The first counts ports that failed a test charge; the second counts causes in one network's monitoring data.

Sources

  1. Open Charge Alliance (2017). Open Charge Point Protocol 1.6, edition 2 (opens in a new tab). §3.5 Local Authorization & Offline Behavior, §4.2 Boot Notification, §4.6 Heartbeat, §4.9 Status Notification, §5.14 Reset, §5.17 Trigger Message, §9.1.10 HeartbeatInterval; accessed 2026-10-22.
  2. Open Charge Alliance (2026). Improved security for OCPP 1.6-J, edition 4 (opens in a new tab). §2.1 Security Profiles, §2.4 TLS with Basic Authentication Profile (A00.FR.309, A00.FR.310); accessed 2026-10-22.
  3. Rempel, Cullen, Matteson Bryan and Vianna Cezar, Human Factors (SAGE) (2023). Reliability of Open Public Electric Vehicle Direct Current Fast Chargers (opens in a new tab). Abstract, Methods and Results; published online 30 November 2023, vol. 66 no. 11 (2024), pp. 2528–2538; accessed 2026-10-22.
  4. National Renewable Energy Laboratory (2024). Impact of Electric Vehicle Charging Station Reliability, Resilience, and Location on Electric Vehicle Adoption, NREL/TP-5R00-89896 (opens in a new tab). §2.2.3 Top Causes of No-Charge Events, Table 4; accessed 2026-10-22.

Talk to us about your chargers

What happens next

  1. Tell us about your network.
  2. Meet a Kinethra specialist.
  3. Get your chargers live on Kinethra.