This page is also available in French. Switch to French

This page is also available in Spanish. Switch to Spanish

PowerMeterFailure: what it means and what to do

"Failure to read electrical/energy/power meter" (OCPP 1.6, §7.6).

Safety first

This fault can come from the charger's electrical components.

Stop charging and don't touch the charger, its cable or the vehicle connector. If it is safe to do so, switch the charger off at its circuit breaker. Only the charger manufacturer or a licensed electrician should inspect or repair it.

What it means

The charger could not read its meter, so energy data for that period may be missing or wrong.

When the status is not Faulted, the error is a warning and charging can continue (OCPP 1.6, §4.9).

Energy.Active.Import.Register must rise monotonically within a transaction (OCPP 1.6, §7.31). A value that drops or resets within a transaction breaks this rule.

Likely causes

OCPP reports that the meter could not be read, not why.

The charger manufacturer can diagnose the cause; the checks below help narrow it down.

First three checks

  • 1.

    Hold billing for every session in the fault window.

  • 2.

    Check that Energy.Active.Import.Register rises monotonically in each transaction (OCPP 1.6, §7.31).

  • 3.

    Did it start after a firmware update?

What to do

  • Safe remote action

    At most one Reset (OCPP 1.6, §5.14). Where billing accuracy is a legal requirement, set the connector Inoperative with ChangeAvailability (OCPP 1.6, §5.2) until the meter is fixed.

  • Dispatch when

    It persists after a reset, or the register is not monotonic. Contact the charger manufacturer.

  • Do not

    Do not bill sessions you have not reviewed.

What to tell the customer

"Your charger couldn't read its energy meter, so the kWh for this session may be inaccurate.

We're reviewing it and won't bill you incorrectly."

A detection rule to start from

When PowerMeterFailure appears, or the register decreases within one transaction: open a metering ticket and hold billing for overlapping sessions.

Sources

  1. Open Charge Alliance (2017). Open Charge Point Protocol 1.6, edition 2 (opens in a new tab). §4.9 Status Notification, §5.2 Change Availability, §5.14 Reset, §7.6 ChargePointErrorCode, §7.31 Measurand.

Talk to us about your chargers

What happens next

  1. Tell us about your network.
  2. Meet a Kinethra specialist.
  3. Get your chargers live on Kinethra.
  • 40,000+ chargers onlineOn the Kinethra platform.
  • OCPP 1.6 and 2.0.1Kinethra works with OCPP chargers from any manufacturer.
  • No commission on charging revenueKinethra takes none.
  1. 01Contact
  2. 02Business
  3. 03Request

Step 1 of 3

We use your details to answer your request. See our Privacy Policy for details.