PowerSwitchFailure: what it means and what to do
"Failure to control power switch" (OCPP 1.6, §7.6). In OCPP 2.0.1 the matching component is PowerContactor, which switches power to the car on and off once authorization and safety requirements are met (OCPP 2.0.1 Appendices, §3.2.43).
Safety first
This fault involves the charger's electrical protection.
Stop charging and don't touch the charger, its cable or the vehicle connector. If it is safe to do so, switch the charger off at its circuit breaker. Only the charger manufacturer or a licensed electrician should inspect or repair it.
Treat every PowerSwitchFailure as a safety signal, and never automate a reset loop.
What it means
The charger could not switch its contactor closed or open ("Close/Open failed", OCPP 2.0.1 Appendices, §3.2.43).
A contactor may have secondary contacts that report whether it is really closed (OCPP 2.0.1 Appendices, §3.2.43).
A failure to close means power cannot be switched on to the car, so the session cannot start. A failure to open is the dangerous case: the power to the car may not have been switched off.
In OCPP 2.0.1
The PowerContactor component reports Problem, "Close/Open failed", or Tripped, "Mirror contact protection tripped".
Active means closed (OCPP 2.0.1 Appendices, §3.2.43).
Likely causes
OCPP reports that switching failed, not why.
The cause is inside the charger, so finding it is a job for the charger manufacturer or a licensed electrician.
First three checks
1.
When did it happen? At the start of a session (close failed) or at the end (open failed)?
2.
Does Current.Import, the current flowing to the car (OCPP 1.6, §7.31), still show a value after the session stopped? Then the power may still be on: keep everyone away and dispatch.
3.
Are chargers of the same model and firmware failing elsewhere? If so, report the pattern to the manufacturer.
What to do
What to tell the customer
"A switching component inside your charger has failed.
We've taken it out of service for safety and will arrange a repair."
A detection rule to start from
On PowerSwitchFailure (in OCPP 2.0.1, PowerContactor Problem or Tripped): raise priority to high, block automated resets, set the connector Inoperative and dispatch.
Sources
- Open Charge Alliance (2017). Open Charge Point Protocol 1.6, edition 2 (opens in a new tab). §4.9, §5.2 Change Availability, §5.14 Reset, §7.6 ChargePointErrorCode, §7.31 Measurand; accessed 2026-10-21.
- Open Charge Alliance (2025). OCPP 2.0.1 Part 2 – Appendices, v1.5 (opens in a new tab). §3.2.43 PowerContactor; accessed 2026-10-21.
Talk to us about your chargers
- Tell us about your network.
- Meet a Kinethra specialist.
- Get your chargers live on Kinethra.
- 40,000+ chargers onlineOn the Kinethra platform.
- OCPP 1.6 and 2.0.1Kinethra works with OCPP chargers from any manufacturer.
- No commission on charging revenueKinethra takes none.
We use your details to answer your request. See our Privacy Policy for details.