This page is also available in French. Switch to French

This page is also available in Spanish. Switch to Spanish

HighTemperature and derating: what it means and what to do

"Temperature inside Charge Point is too high" (OCPP 1.6, §7.6).

Safety first

This fault involves the charger's electrical protection.

Stop charging and don't touch the charger, its cable or the vehicle connector. If it is safe to do so, switch the charger off at its circuit breaker. Only the charger manufacturer or a licensed electrician should inspect or repair it.

Never automate a reset loop.

What it means

OCPP 1.6 has no separate derating message.

When the status is not Faulted, an error is a warning and charging can continue (OCPP 1.6, §4.9). If the charger lowers its output, the lower limit may show as a lower Current.Offered, the maximum current offered to the car (OCPP 1.6, §7.31).

Likely causes

OCPP reports that the temperature inside the charger is too high, not why.

Outdoor heat is one factor (see the industry data below). Anything inside the charger is for the manufacturer or a licensed electrician to inspect.

First three checks

  • 1.

    Is it a warning (still Charging) or a fault (Faulted)?

  • 2.

    Plot Temperature and Current.Offered against time and outdoor temperature. If the charger reports RPM (fan speed), plot that too (OCPP 1.6, §7.31).

  • 3.

    Are same-model chargers nearby affected too, or only this one?

What to do

  • Safe remote action

    A lower limit with SetChargingProfile (OCPP 1.6, §5.16) reduces the current, and with it the load on the charger. A Reset does not fix overheating and may hide the evidence.

  • Dispatch when

    Faulted, repeated derating in mild weather, or a burning smell or discoloured connector, which is a safety call.

  • Do not

    Do not reset to clear it.

What to tell the customer

"Your charger got too warm and slowed down or paused charging to protect itself.

We'll check it if this keeps happening. If you notice a burning smell or a discoloured connector, stop using it and contact us."

A detection rule to start from

When HighTemperature repeats in mild weather: open a ticket for the manufacturer or an electrician to check the charger's cooling.

What industry data shows

NREL reports that DC fast charger specification sheets typically list operating temperatures of −30°F to 130°F, that performance falls in both extreme heat and extreme cold within this range, and that in regions with these extremes chargers can deliver less power than rated, or none (NREL, August 2024).

Sources

  1. Open Charge Alliance (2017). Open Charge Point Protocol 1.6, edition 2 (opens in a new tab). §4.9 Status Notification, §5.14 Reset, §5.16 Set Charging Profile, §7.6 ChargePointErrorCode, §7.31 Measurand.
  2. National Renewable Energy Laboratory (2024). Impact of Electric Vehicle Charging Station Reliability, Resilience, and Location on Electric Vehicle Adoption, NREL/TP-5R00-89896 (opens in a new tab). §5.3.1 EVSE Performance; accessed 2026-10-22.

Talk to us about your chargers

What happens next

  1. Tell us about your network.
  2. Meet a Kinethra specialist.
  3. Get your chargers live on Kinethra.