OverCurrentFailure: what it means and what to do

"Over current protection device has tripped" (OCPP 1.6, §7.6). Treat repeated trips as a safety signal.

Safety first

This fault involves the charger's electrical protection.

Stop charging and don't touch the charger, its cable or the vehicle connector. If it is safe to do so, switch the charger off at its circuit breaker. Only the charger manufacturer or a licensed electrician should inspect or repair it.

Remote commands restart software. They cannot repair hardware or make an installation safe, so never automate a reset loop.

What it means

OverCurrentFailure is an OCPP 1.6 error code.

In OCPP 2.0.1 the matching component is OverCurrentProtection, which protects equipment by disconnecting the electrical supply when the current drawn on any phase exceeds the rated value to a substantial degree (OCPP 2.0.1 Appendices, §3.2.41).

Likely causes

OCPP reports that the protection tripped, not why.

Either the vehicle or the installation can be the source, and the checks below help the manufacturer or a licensed electrician tell which.

First three checks

  • 1.

    Compare Current.Import with Current.Offered and the rated current (OCPP 1.6, §7.31).

  • 2.

    One vehicle or many?

  • 3.

    Compare the configured maximum current with the breaker size recorded at installation.

What to do

  • Safe remote action

    At most one Reset after a single trip, and only if the manufacturer allows it. A lower limit with SetChargingProfile (OCPP 1.6, §5.16) while you investigate.

  • Dispatch when

    A repeat trip, or any trip where you cannot verify the configured limit.

  • Do not

    Do not repeat resets.

What to tell the customer

"Your charger's overcurrent protection switched off the power.

We'll check whether the car or the installation drew more current than it should."

A detection rule to start from

When OverCurrentFailure repeats on one connector: raise priority to high and group events by idTag to separate a car fault from an installation fault.

Sources

  1. Open Charge Alliance (2017). Open Charge Point Protocol 1.6, edition 2 (opens in a new tab). §5.14 Reset, §5.16 Set Charging Profile, §7.6 ChargePointErrorCode, §7.31 Measurand.
  2. Open Charge Alliance (2025). OCPP 2.0.1 Part 2 – Appendices, v1.5 (opens in a new tab). Chapter 3, standardized components: §3.2.41 OverCurrentProtection.

Talk to us about your chargers

What happens next

  1. Tell us about your network.
  2. Meet a Kinethra specialist.
  3. Get your chargers live on Kinethra.
  • 40,000+ chargers onlineOn the Kinethra platform.
  • OCPP 1.6 and 2.0.1Kinethra works with OCPP chargers from any manufacturer.
  • No commission on charging revenueKinethra takes none.