This page is also available in French. Switch to French

This page is also available in Spanish. Switch to Spanish

UnderVoltage: what it means and what to do

"Voltage has dropped below an acceptable level" (OCPP 1.6, §7.6).

Safety first

This fault involves the charger's electrical protection.

Stop charging and don't touch the charger, its cable or the vehicle connector. If it is safe to do so, switch the charger off at its circuit breaker. Only the charger manufacturer or a licensed electrician should inspect or repair it.

Never automate a reset loop.

What it means

UnderVoltage is an OCPP 1.6 error code.

In OCPP 2.0.1, a charger reports monitoring events, such as a monitored value crossing a threshold, in NotifyEvent messages about components and variables (OCPP 2.0.1, N07).

Likely causes

OCPP reports that the voltage was too low, not why.

The cause can lie in the building's wiring, the grid or the charger, so finding it is a job for a licensed electrician or the charger manufacturer. Voltage readings from this charger and others on the same supply help them.

First three checks

  • 1.

    When does it happen: at plug-in, at the start of current flow, or at random?

  • 2.

    Did it clear when the voltage recovered (transient), or stay (latched)?

  • 3.

    Compare Voltage samples with other chargers on the same feed. Add Voltage to MeterValuesSampledData if it is missing (OCPP 1.6, §3.16, §7.31).

What to do

  • Safe remote action

    One Reset if the voltage is normal now; a soft reset stops the session gracefully (OCPP 1.6, §5.14). A lower limit with SetChargingProfile (OCPP 1.6, §5.16) reduces the current drawn while the supply is checked.

  • Dispatch when

    It returns after one reset, or the voltage is outside the manufacturer's range. Send an electrician.

  • Do not

    Do not reset in a loop.

What to tell the customer

"Your charger stopped because the supply voltage dropped too low.

An electrician should check the supply to your charger."

A detection rule to start from

When UnderVoltage repeats, or returns after a Reset: open a ticket for a site supply check by an electrician and stop automatic resets.

Sources

  1. Open Charge Alliance (2017). Open Charge Point Protocol 1.6, edition 2 (opens in a new tab). §3.16 Metering Data, §5.14 Reset, §5.16 Set Charging Profile, §7.6 ChargePointErrorCode, §7.31 Measurand.
  2. Open Charge Alliance (2025). OCPP 2.0.1 Edition 4, Part 2 – Specification (opens in a new tab). N07 Alert Event (NotifyEvent); §2.22 EventDataType.

Talk to us about your chargers

What happens next

  1. Tell us about your network.
  2. Meet a Kinethra specialist.
  3. Get your chargers live on Kinethra.
  • 40,000+ chargers onlineOn the Kinethra platform.
  • OCPP 1.6 and 2.0.1Kinethra works with OCPP chargers from any manufacturer.